Name inventory
|
Tech.characteristics |
Application |
Image |
6.5 digit Precision Multimeter 8846A
|
DCV accuracy up to 0,0024 %. DCV 100 mV – 1000 V, ACV 100 mV – 1000 V, DCA 100 μA – 10 A, ACA 100 mA – 10 A, Resistance 10 Ω – 1 GΩ, Frequency 3 Hz – 1 MHz, Capacitance 1 nF – 0,1 F, Temperature -200 °C to 600 °C. Using RS-232 or GPIB bus can be connected to a computer and controlled with a Labview program of Fluke program.
|
Measurement of electric voltage or current, load resistance, measurement of signal frequency and period, measurement of capacitance and temperature.
|
|
6.5 digit Precision Multimeter 8845A
|
DCV accuracy up to 0,0035 %, DCV 100 mV – 1000 V, ACV 100 mV – 1000 V, DCA 100 μA – 10 A, ACA 100 mA – 10 A. Resistance 100 Ω – 100 MΩ, Frequency 3 Hz – 300 kHz.
|
Measurement of electric voltage or current, load resistance, measurement of signal frequency and period, measurement of capacitance and temperature.
|
|
4.5 digit Multimeter UT71E
|
DCV accuracy (0.025 %+5d). DCV 400 mV – 1000 V, ACV 4 V – 1000 V, DCA 400 μA – 10 A, ACA 400 μA – 10 A, Resistance 400 Ω – 40 MΩ, Frequency 40 Hz – 400 MHz, Capacitance 40 nF – 40 mF, Temperature -40 °C do 1000 °C. Power of single phase load, up to 2500 W. Using USB can be connected to a computer and controlled with a program.
|
Measurement of electric voltage or current, load resistance, measurement of signal frequency and period, measurement of capacitance, temperature and power.
|
|
3.5 digit Multimeter M3900, 12 pieces
|
DCV accuracy (0.5 %+1d). DCV 200 mV – 1000 V, ACV 200 mV – 750 V, DCA/ACA 20 μA – 20 A, Resistance 200 Ω – 20 MΩ.
|
Measurement of electric voltage or current and load resistance.
|
|
Multimeter High Voltage Probe for a 20 kV
|
DC do 40 kV. AC do 28 kV RMS. Accuracy ± 2 % (20 kV), ± 3 % (20 kV – 40 kV).
|
Measurement of DC and AC high voltages.
|
|
GPIB Interface for communication of computer and instruments
|
GPIB to USB.
|
Communiction of instrument with computer.
|
|
RS 232 Interface for communication of computer and instrument, 3pieces
|
RS 232 to USB.
|
Communiction of instrument with computer.
|
|
Miniature Reference Temperature Thermistor Probe 5665
|
0 °C do 100 °C. Točnost ±0,01 °C.
|
Calibration of temperature probes.
|
|
Temperature thermistor probe USP8528-ND, 8 pieces
|
-55 °C to 125 °C. Accuracy ±0,2 °C (25 °C to 80 °C).
|
Temperature measurement of liquids.
|
|
Logger Hygrothermometer NT2-D
|
0 – 100 % RH, -30 °C do 70 °C. Accuracy 1.5 %RH, 0.2 °C.
|
Measurement of air temperature and humidity.
|
|
Data acquisition measurement card NI PCI 6281
|
8 differential/16 referenced input channels with 18 bits resolution, 2 analog output channels with 16 bit resolution, 24 DIO, measurement ranges from ± 100 mV to ±10 V. Sample rate 650 kS/s one channel, multichannel 500 kS/s.
|
Temperature measurement, measurement of deformations, measurement of electric detonators properties.
|
|
Four channel oscilloscope WaveRunner 6030, 350 MHz
|
Analog bandwidth 350 MHz @ 50 Ω, rise time 1 ns, 8 bits of resolution on 4 channels.
|
Measurement of fast changing signals, voltage, current of transducer signals (e.g. strain gauges, …).
|
|
Oscilloscope High Voltage Probe for a 20 kV
|
Max. voltage 20 kV including peak AC, max. 14 kV RMS AC (50 Hz/60 Hz). Max. 40 kV peak pulse. Bandwidth 100 MHz.
|
Measurement of static and dynamic high voltage signals.
|
|
Transducer MI400
|
Measurement of more than 50 different power source parameters (V, A, kW, kVA, malfunction, power factor, Hz,…) with three analog outputs and communication with computer. Accuracy class 0.5
|
Measurement of power supply properties.
|
|
Precission current shunt CS-10, with temperature sensor
|
Max. current 10 A, resistance 0,1 Ω. Accuracy 0,01 %. DC/AC difference 0,01 % to 20 kHz.
|
Measurement of DC, AC or pulse currents. Reference for other current measuring devices. Measurement of firing pulse of electric detonators.
|
|
Current shunt SB 101, 2 pieces
|
Max. current 30 A, resistance 3.33 mΩ. Accuracy 0.5 %.
|
Measurement of DC, AC or pulse currents. Measurement of firing pulse of electric detonators.
|
|
Wideband Current Transformer 2-0.1W
|
Output (V/A) 0.1. Accuracy 0.5 % Max. current peak 5000 A. Max. rms AC current 65 A. Rise time 20 ns. Frequency 1 Hz – 20 MHz.
|
Measurement of electric current, powers (P, Q, S) and power factor of monophase load can be calculated. Measurement of high voltage conductor currents.
|
|
Wideband Current Transformer model 6600
|
Output (V/A) 0.1. Accuracy 1 % Max. current peak 2000 A. Max. rms AC current 40 A. Rise time 5 ns. Frequency 25 Hz – 120 MHz.
|
Measurement of electric current, powers (P, Q, S) and power factor of monophase load can be calculated. Measurement of high voltage conductor currents.
|
|
Wideband Current Transformer model 6585
|
Output (V/A) 0.1. Accuracy 1 % Max. current peak 500 A. Max. rms AC current 10 A. Rise time 1.5 ns. Frequency 400 Hz – 250 MHz.
|
Measurement of electric current, powers (P, Q, S) and power factor of monophase load can be calculated. Measurement of high voltage conductor currents.
|
|
Current Transformer MSZ 1576, 10 pieces
|
Measurement ranges 15 A, 50 A, 100 A, 200 A, 300 A, 400 A, 600 A. Accuracy 0.2 %
|
Measurement of rms AC currents.
|
|
Multichannel Arbitrary DC Power Supply Unit HM8143
|
Two outputs (0 V– 30 V)/2 A and output with fixed voltage 5 V/2 A. Two outputs can work as amplifier with amplification of 3. One channel can work as signal generator (12 bits/4096 points) with output current <2 A.
|
Power supply of loads or sensors/transducers that need regulated voltage or current for operation.
|
|
High voltage DC power source MK40P1.8.
|
Type MK, up to 40 kV (5 % to 100 %), 75 W, 1.8 mA.
|
For Detonator sensitivity testing to high voltage disharges.
|
|
Stereo sound and noise recorder TASCAM US-122
|
Sample rate 48 kHz, 24 bit resolution, 16 MIDI I/O channels.
|
Sound or noise signals recording which enables saving data to the computer and later analysis.
|
|
Measurement condenser microphone ECM 8000, 2 pieces
|
Impedance 200 ohms, sensitivity 70 dB, freq. response 20 Hz – 20 000 Hz, phantom power +15 V to 48 V, gold plated XLR connector.
|
Omnidirectional ultra linear microphone for measurement and recording applications.
|
|